24/7 customer assisting
There are 24/7 customer assisting to support you in case you may encounter some problems like downloading. Please feel free to contact us if you have any questions.
Instant Download E20-554 Exam Braindumps: Upon successful payment, Our systems will automatically send the product you have purchased to your mailbox by email. (If not received within 12 hours, please contact us. Note: don't forget to check your spam.)
One-year free update
We offer the one-year free update Isilon Design Specialist Exam for Technology Architects test questions once you purchased. And once there is latest version released, our system will send the latest valid Isilon Design Specialist Exam for Technology Architects dumps to your email immediately.
Full refund
If you failed the exam with our valid Isilon Design Specialist Exam for Technology Architects vce, we promise you to full refund. Or you can choose to wait the updating or free change to other dumps if you want.
As one of high-quality and authoritative exam, passing valid EMC exam is a long and tough task for most IT professionals, especially for people who have no enough time to prepare the Isilon Design Specialist Exam for Technology Architects test questions. So choosing right study materials are necessary and important to people who want to passing Isilon Design Specialist Exam for Technology Architects actual test quickly at first attempt. Valid EMC Certification dumps provided by our website are effective tools to help you pass exam. We provide customers with the most reliable valid Isilon Design Specialist Exam for Technology Architects vce and the most comprehensive service.
Our website are specialized in offering customers with valid E20-554Isilon Design Specialist Exam for Technology Architects dumps and study guide, which written by a team of IT experts and certified trainers who have rich experience in the study of valid Isilon Design Specialist Exam for Technology Architects exam. All Isilon Design Specialist Exam for Technology Architects test questions are created based on the real test. Besides, we always check the updating of valid Isilon Design Specialist Exam for Technology Architects vce to ensure the preparation of exam successfully.
Choosing valid E20-554 Isilon Design Specialist Exam for Technology Architects dumps means closer to success. Before you buy our products, you can download the free demo of Isilon Design Specialist Exam for Technology Architects test questions to have a try. Comparing to other training institution, our valid Isilon Design Specialist Exam for Technology Architects vce are affordable, latest and effective, which can overcome the difficulty of valid Isilon Design Specialist Exam for Technology Architects exam and ensure you pass the exam. It can not only save your time and money, but also help you pass Isilon Design Specialist Exam for Technology Architects actual test with high rate.
The most important, you just need to spend one or two days to practice Isilon Design Specialist Exam for Technology Architects test questions and remember the Isilon Design Specialist Exam for Technology Architects test answers, you will find passing Isilon Design Specialist Exam for Technology Architects is so easy.
EMC Isilon Design Specialist Exam for Technology Architects Sample Questions:
1. You have been working with a customer to size a new Isilon cluster for their environment. You recently determined that a cluster with three X400 nodes with 1TB drives and 48 GB RAM would be a perfect starting point for their workflow, but will have extra capacity. The customer just informed you that they have decided to also use the cluster for a small home directory environment and implement SmartQuotas.
Which configuration changes should you consider?
A) Add an additional X400-Series node to the configuration.
B) Increase the memory and add SSDs to the configuration.
C) Add three S-Series nodes with 300GB drives with 48GB RAM, and use SmartPools
D) Add three NL-Series nodes with 1 TB drives with 48GB RAM, and use SmartPools.
2. -- Exhibit -
A European Sports TV network is considering Isilon for their Media Edit Storage for their editing workloads. They are also considering Isilon for near-line media archiving.
The network receives XDCAM HD footage which is loaded onto their existing Transcoding Storage platform. New footage that needs to be edited will be transferred from their Transcoding Storage platform to the proposed Media Edit Storage platform at the rate of ten simultaneous XDCAM HD files via FTP. Edited files will be transferred back to the Transcoding Storage platform at the rate of ten simultaneous XDCAM HD files via FTP.
The network currently has 15 Final Cut Pro edit stations, 15 Avid edit stations. Proxy software will be used to allow Isilon to act as the storage for the Final Cut Pro and Avid media. Three of those edit stations will be performing content compositing as needed.
The network expects 70 hours of new content per week, and 50 hours of edited content per week. They intend to keep the new and edited content on the proposed Media Edit Storage as a performance tier for 30 days. They would like to retain all new and edited footage proposed Media Edit Storage as a near-line tier for two years.
In addition to the current workloads, the network expects to implement a new Media Asset Management (MAM) solution and has requested the Isilon cluster be capable of supporting 120 MBps read and 120 MBps write to support the MAM requirements.
-- Exhibit -
Refer to the exhibit.
Based on the number of edit stations, and their intended use, what bandwidth requirements should be considered while sizing?
A) Write Performance: 21 MBps FTP sequential 70 MBps NFS and/or SMB sequential 120 MBps NFS and/or SMB random Read Performance: 210 MBps FTP sequential 70 MBps NFS and/or SMB sequential 120 MBps NFS and/or SMB random
B) Write Performance: 550 MBps FTP sequential 275 MBps NFS and/or SMB sequential 120 MBps NFS and/or SMB random Read Performance: 550 MBps FTP sequential
1.6 GBps NFS and/or SMB sequential 120 MBps NFS and/or SMB random
C) Write Performance: 70 MBps FTP sequential 210 MBps NFS and/or SMB sequential 120 MBps NFS and/or SMB random Read Performance: 70 MBps FTP sequential 21 MBps NFS and/or SMB sequential 120 MBps NFS and/or SMB random
D) Write Performance: 70 MBps FTP sequential 21 MBps NFS and/or SMB sequential 120 MBps NFS and/or SMB random Read Performance: 70 MBps FTP sequential 210 MBps NFS and/or SMB sequential 120 MBps NFS and/or SMB random
3. -- Exhibit -
We have been engaged by a research hospital to help upgrade their Isilon installation. They currently have 12 previous generation Isilon nodes with 200TB of capacity and run on a 1Gbps network. They currently have 6 Illumina Hi-Seq Sequencers and an HPC cluster to process data. They would like to expand Isilon to 2PB of active data and 1PB of archive data. They use a third party data and metadata management service (IRODs) to stage data for analysis. The Isilon cluster is mainly used for analysis work with the HPC cluster.
-- Exhibit -
Currently, the workflows are being limited by the network access to the Isilon cluster.
What would result in the fastest possible network throughput?
A) Implement jumbo frames.
B) Move analysis infrastructure to dedicated 10G network.
C) Add four A-Series accelerator nodes.
D) Use LACP to aggregate the network connections.
4. Your customer purchased an Isilon cluster with eight X400 nodes for Home Directories. Your follow-up discussions have uncovered an opportunity to expand the cluster to support the Legal Department. As you prepare to complete the Workflow Profile Document, you meet with the customer to discuss data protection.
Which key areas should you address?
A) Default cluster protection level Additional directory level protections Snapshots and replication
B) Protocols (SMB, NFS, FTP, HTTP, HDFS) Authentication and Directory Services Performance and latency concerns
C) Default cluster protection level Backup windows and processes Concurrency of user access
D) WORM requirements Network ports for replication Snapshots for user restores
5. A hospital is considering using Isilon to store their archived medical images and genomic sequencing data. They currently have 56 TB of PACS images and 24 TB of genomic data, and expect to double their capacity requirements this year. They will replicate to a DR cluster, and plan to use N+2 protection. The production workload needs to be run at either site.
Which minimum cluster configuration, at each site, including software, would meet this customer's environment?
A) Five X400 (2 TB drives) nodes with SnapshotIQ.
B) Four NL400 (3 TB drives) nodes with SyncIQ.
C) Seven X200 (3 TB drives) nodes with SyncIQ and SnapshotIQ
D) Five X400 (2 TB drives) nodes with SyncIQ.
Solutions:
| Question # 1 Answer: B | Question # 2 Answer: D | Question # 3 Answer: B | Question # 4 Answer: A | Question # 5 Answer: D |






