As one of high-quality and authoritative exam, passing valid FileMaker exam is a long and tough task for most IT professionals, especially for people who have no enough time to prepare the Developer Essentials for FileMaker 12 Beta Exam test questions. So choosing right study materials are necessary and important to people who want to passing Developer Essentials for FileMaker 12 Beta Exam actual test quickly at first attempt. Valid FileMaker Certification dumps provided by our website are effective tools to help you pass exam. We provide customers with the most reliable valid Developer Essentials for FileMaker 12 Beta Exam vce and the most comprehensive service.
Our website are specialized in offering customers with valid FM1-306Developer Essentials for FileMaker 12 Beta Exam dumps and study guide, which written by a team of IT experts and certified trainers who have rich experience in the study of valid Developer Essentials for FileMaker 12 Beta Exam exam. All Developer Essentials for FileMaker 12 Beta Exam test questions are created based on the real test. Besides, we always check the updating of valid Developer Essentials for FileMaker 12 Beta Exam vce to ensure the preparation of exam successfully.
Choosing valid FM1-306 Developer Essentials for FileMaker 12 Beta Exam dumps means closer to success. Before you buy our products, you can download the free demo of Developer Essentials for FileMaker 12 Beta Exam test questions to have a try. Comparing to other training institution, our valid Developer Essentials for FileMaker 12 Beta Exam vce are affordable, latest and effective, which can overcome the difficulty of valid Developer Essentials for FileMaker 12 Beta Exam exam and ensure you pass the exam. It can not only save your time and money, but also help you pass Developer Essentials for FileMaker 12 Beta Exam actual test with high rate.
The most important, you just need to spend one or two days to practice Developer Essentials for FileMaker 12 Beta Exam test questions and remember the Developer Essentials for FileMaker 12 Beta Exam test answers, you will find passing Developer Essentials for FileMaker 12 Beta Exam is so easy.
One-year free update
We offer the one-year free update Developer Essentials for FileMaker 12 Beta Exam test questions once you purchased. And once there is latest version released, our system will send the latest valid Developer Essentials for FileMaker 12 Beta Exam dumps to your email immediately.
Full refund
If you failed the exam with our valid Developer Essentials for FileMaker 12 Beta Exam vce, we promise you to full refund. Or you can choose to wait the updating or free change to other dumps if you want.
24/7 customer assisting
There are 24/7 customer assisting to support you in case you may encounter some problems like downloading. Please feel free to contact us if you have any questions.
Instant Download FM1-306 Exam Braindumps: Upon successful payment, Our systems will automatically send the product you have purchased to your mailbox by email. (If not received within 12 hours, please contact us. Note: don't forget to check your spam.)
FileMaker Developer Essentials for FileMaker 12 Beta Sample Questions:
1. A developer creates a database with the following Custom Menu settings installed as the file default:
Custom Menu settings:
The New Record command has an override title of New Order
The Delete Record command has an override title of Delete Order
The Save/Send Records As > PDF command has an override title of Order Report Assume buttons for these are on the Status Toolbar. The file is hosted and subsequently opened by a user with a privilege set which prohibits deletion of records.
Which statement is true about this situation?
A) Buttons named New Order, Delete Order, and Order Report are visible and appear available, but the Delete Report button generates an alert when it is clicked.
B) Buttons named New Record and Delete Record are visible, but the Delete Record button is grayed out.
C) Buttons named New Record, Delete Record, and Save as PDF are visible, but the Delete Record button is grayed out.
D) A button named New Order is visible and available, a button named Delete Order is visible but grayed out.
2. Which two statements are true about field indexing in FileMaker Pro 12? (Choose two.)
A) Minimal indexing indicates that either the value index or the word index has been created, but not both
B) To establish a relationship between two fields, both fields are required to be indexed.
C) A field must be indexed in order for Auto-complete using previously entered values to function.
D) Calculation fields cannot be indexed.
E) Indexing improves the speed at which sorts are performed.
3. What is the minimal requirement to add an external FileMaker Data Source table occurrence of Inventory from a file called DEPT to the Relationships Graph of a file called PROD?
A) an active account associated with a privilege set that has the Manage External Data Sources option checked in both PROD and DEPT
B) an active account associated with any privilege set in PROD, and an active account associated with a privilege set that has view record access for the Inventory table
C) an active account in DEPT associated with a privilege set that has the Manage External Data Sources option checked, and an active account with the [Full Access] privilege set in PROD
D) an active account associated with the [Full Access] privilege set in PROD and an active account in DEPT associated with a privilege set that has view record access for the Inventory table
E) an active account associated with the [Full Access] privilege set in both PROD and DEPT
4. Which statement is true about portals in FileMaker Pro 12?
A) Conditional formatting can be applied to a portal row.
B) If there are multiple portals on a layout, the Go to Portal Row [First] script step will activate the portal closest to the top left corner of the layout.
C) A portal set with only a bottom anchor containing fields set with only a top anchor will increase row height as the layout is expanded vertically.
D) Records in a portal can become unsorted if the developer unchecks "Keep records in sorted order" in the Portal Setup > Sort Records dialog.
E) An OnObjectEnter script trigger applied to a portal will activate once for each portal row as a user tabs from field to field across rows.
5. The text field productCode has a script trigger set to activate OnObjectKeystroke and runs the following script:
If [Length (File::productCode) > 7]
Exit Script [Result: 0]
Else
Set Field [File::productCode; File::productCode & "-"]
End If
The field productCode has the value of 12-1415. A user types a 6 in the field at the end of the value.
What is the resulting value in the field after the script trigger has processed?
A) 12-1415-
B) 12-1415-6
C) 12-14156
D) 12-1415
E) 12-14156-
Solutions:
Question # 1 Answer: D | Question # 2 Answer: A,C | Question # 3 Answer: D | Question # 4 Answer: E | Question # 5 Answer: B |